Search

Custom Search
Showing posts with label Errors. Show all posts
Showing posts with label Errors. Show all posts

Wednesday, October 30, 2013

CORBA Initialization failed. (WIS 10901) error in WebI Rich Client

 

Today we faced a power frailer in our building. I was using Rich client and logged in by user name & password. After My PC was restarted I able to do the following:

  • Login to rich client.
  • Navigate to a Webi report and open it in rich client.

When I tried to refresh any report from Rich client I got the following error Message:

Query Name – Universe Name

A database error occurred. The database error text is: (CS) “COBRA Initialization failed”. (WIS 10901)

10-29-2013 10-52-46 AM

Error Message:

Code: WIS 10901

Error Message: A database error occurred. The database error text is: (CS) “COBRA Initialization failed”.

Application: Rich Client

Environment: BO XI3.1

 

Notes:

  • You will be able to refresh the data in the same report If you tried to login to info view and refresh it from there.

 

Resolution:

Resolution Method # 1: Don’t log to the JR2 system. Log into the original one. The error message will be displayed if you tried to login to the system beside the (?)

10-29-2013 10-55-34 AM

Resolution Method # 2: Restart the connection server from CMS